Rotary tablet press machine maintenance instructions
1. A use is completed or stop working, should take out the remaining powder, brush the machine parts of the residual powder, such as stop using time is longer, must be removed all the punch mold, and all the machine wipe clean, the machine parts of the glossy surface coated with antirust oil, with a cloth canopy cover good.
2. The use of places should be cleaned often, especially for medicine and edible tablets manufacturing should not have gray sand, dust.
3. The maintenance of the die should be placed in a covered tin box, so that the die all punch all immersed in oil, and to keep clean, do not make rust and bruises, recommended customized iron box to each specification in a box, can avoid the use of the wrong and help to grasp the situation of damage.
4. Regular inspection of machine parts, 1-2 times a month, check the project for the worm wheel, worm gear, bearings, pressure, crankshaft, upper and lower rail guide and other active parts of the rotation and wear and tear, found defects should be repaired in time to use.
Rotary tablet press installation instructions
1. The installation of electrical wiring, should pay attention to the voltage, the user did not propose, always stipulated as 380 volts, and in the wiring should pay attention to the direction of rotation of the motor, must be the same as the arrow on the machine, do not reverse, in order to ensure electrical safety must be installed to connect the effective ground wire.
2. The machine is a whole box, unpacked and moved to the appropriate use of the place, padded and can be used, such as the status of the fixed can be added to the foot pegs.
3. The machine should be installed in a dry, clean, well-lit room.